Contents Index Publication property sheet: Connection tab Publisher property sheet

SQL Anywhere Studio Help
  Adaptive Server Anywhere Help
    Introduction to property sheets
      Publication property sheet

Publication property sheet: Extended Options tab

The Extended Options tab of the Publication property sheet has the following components:

The table below lists all the available extended options for synchronization.

For more information about these options, see -e extended options.

Extended option Default Description
CommunicationAddress (adr) extended option '' Specifies the communication address for connecting to the MobiLink server.

For allowed values, see CREATE SYNCHRONIZATION USER statement [MobiLink].

CommunicationType (ctp) extended option '' Specifies the communication type for connecting to the MobiLink server.

For allowed values, see CREATE SYNCHRONIZATION USER statement [MobiLink].

ConflictRetries (cr) extended option -1 (continue indefinitely) Specifies the number of retries if the download fails because of conflicts.
DisablePolling (p) extended option OFF Disables automatic logscan polling.
DownloadBufferSize (dbs) extended option 32 K on Windows CE, 1 M on all other operating systems. Specifies the size of the download buffer.

By default, units of bytes are used. You can use the suffix k or m to to specify units of kilobytes or megabytes, respectively.

DownloadOnly (ds) extended option OFF Specifies that synchronization should be download-only.
ErrorLogSendLimit (el) extended option 32 K Specifies how much of the remote log file dbmlsync should send to the server when synchronization occurs.

By default, units of bytes are used. You can use the suffix k or m to to specify units of kilobytes or megabytes, respectively. If you don't want to send any dbmlsync output log messages, a zero value should be set for this extended option.

FireTriggers (ft) extended option ON Specifies that triggers should be fired on the remote database when the download is applied.
HoverRescanThreshold (hrt) extended option 1 M When you are using scheduling, this limits the amount of discarded memory that is allowed to accumulate before a rescan is performed.

By default, units of bytes are used. You can use the suffix k or m to to specify units of kilobytes or megabytes, respectively.

IgnoreHookErrors (eh) extended option OFF Specifies that errors that occur in hook functions should be ignored.
IgnoreScheduling (isc) extended option OFF Specifies that scheduling settings should be ignored.
Increment (inc) extended option (infinite) Controls the size of incremental uploads.

By default, units of bytes are used. You can use the suffix k or m to to specify units of kilobytes or megabytes, respectively.

LockTables (lt) extended option ON Specifies that articles (tables or parts of tables in the publications being synchronized) should be locked before synchronizing.
Memory (mem) extended option 1 M Specifies a cache size.

By default, units of bytes are used. You can use the suffix k or m to to specify units of kilobytes or megabytes, respectively.

MobiLinkPwd (mp) extended option NULL Specifies the MobiLink password.
NewMobiLinkPwd (mn) extended option NULL Specifies a new MobiLink password.
OfflineDirectory (dir) extended option NULL Specifies the path containing offline transaction logs.
PollingPeriod (pp) extended option 1 minute Specifies the logscan polling period.

By default, units of minutes are used. You can use the suffix s, m, h, or d to specify units of seconds, minutes, hours, or days, respectively.

Schedule (sch) extended option No schedule Specifies a schedule for synchronization.
ScriptVersion (sv) extended option DEFAULT Specifies a script version.
SendColumnNames (scn) extended option OFF Specifies that column names should be sent in the upload.
SendDownloadACK (sa) extended option OFF Specifies that a download acknowledgement should be sent from the client to the server.
SendTriggers (st) extended option OFF Specifies that trigger actions should be sent on upload.
TableOrder (tor) extended option (none) Specifies the order of tables in the upload stream.
UploadOnly (uo) extended option OFF Specifies that synchronization should only include an upload.
Verbose (v) extended option OFF Specifies full verbosity.

This option is identical to dbmlsync -v+.

VerboseHooks (vs) extended option OFF Specifies that messages related to hook scripts should be logged.

This option is identical to dbmlsync -vs.

VerboseMin (vm) extended option OFF Specifies that a small amount of information should be logged.

This option is identical to dbmlsync -v.

VerboseOptions (vo) extended option OFF Specifies that information should be logged about the command line options (including extended options) that you have specified.

This option is identical to dbmlsync -vo.

VerboseRowCounts (vn) extended option OFF Specifies that the number of rows that are uploaded and downloaded should be logged.

This option is identical to dbmlsync -vn.

VerboseRowValues (vr) extended option OFF Specifies that the values of rows that are uploaded and downloaded should be logged.

This option is identical to dbmlsync -vr.

VerboseUpload (vu) extended option OFF Specifies that information about the upload stream should be logged.

This option is identical to dbmlsync -vu.

Note 

You can set extended options for synchronization in the following ways:

When you store extended options and connection parameters in the database, dbmlsync reads the information from the database. If values are specified in both the database and the command line, the value strings are combined. If conflicting values are specified, dbmlsync resolves them as follows, where values occurring earlier in the list take precedence over those occurring later in the list:

For example, if you specify FireTriggers=OFF using the -e option on the command line, and you specify FireTriggers=ON for the publication, synchronization is attempted using the -e option setting (FireTriggers=OFF).

If a field is blank on the Extended Options tab of the Publication property sheet, the publication may be inheriting the extended option value from the -e option, the -eu option, the synchronization subscription, or the MobiLink user. You should only supply extended option values on the Extended Options tab of the Publication property sheet if you want to override these other values.


Contents Index Publication property sheet: Connection tab Publisher property sheet